Add to Cart
Temperature & Humidity & Vibration Combined Test Chamber
Application:
Vibration test Chamber Temperature Humidity Calibrator Equipment integrated temperature, humidity, vibration of the three functions of the test box.With rapid temperature change rate, temperature, and humidity integrated test environment and the vibration function.
Combined environmental test equipment provides the change of temperature and humidity environment for the aerospace, aviation, petroleum, chemical, electronics, communication and other scientific research and production units, at the same time in the test chamber electric vibration stress according to the provisions of the cycle is applied to the sample, for the user of the machine (or components), electrical appliances, instruments, materials etc. temperature and humidity, vibration stress screening test, in order to assess product adaptability or experiment on behavior evaluation.
Feature
1. Multifunctional - can be used as a single temperature / humidity test chamber, to maximise your return on investment.
2. The viewing window is larger than the previous model, to ease inspection of the specimen during test. A heater inside the door prevents dew appearance.
3. Rail to move the chamber back and forth, coupling shaft diameter selection.
4. A heater inside the door prevents dew appearance.
5. Simulation test environment three environmental factors in the same cabinet.
6. Receive customized design, satisfy the strict user demand conditions.
7. High performance, fast temperature change rate, can be accelerated stress testing products.
Unit | 4060-5 | 7060-5 | 4120-5 | 7120-5 | 4220-5 | 7220-5 |
4060-10 | 7060-10 | 4120-10 | 7120-10 | 4220-10 | 7220-10 | |
4060-15 | 7060-15 | 4120-15 | 7120-15 | 4220-15 | 7220-15 | |
(L) | 600 | 1200 | 2200 | |||
℃ | -40/+180 | -70/+180 | -40/+180 | -70/+180 | -40/+180 | -70/+180 |
℃ | ±0.1~±0.8 | |||||
℃ | ±0.5~±2.0 | |||||
℃/min | 5℃/min,10℃/min,15℃/min,20℃/min,25℃/min,30℃/min,35℃/min,40℃/min, | |||||
( SMV series) | ||||||
℃ | +10~+95 | |||||
℃ | ±0.1~±0.5 | |||||
℃ | ±0.5~±1.0 | |||||
℃/min | 10-95(98%r,h. When used in conjunction with the Blind) | |||||
℃/min | ±1~±3 | |||||
℃ | +4to+94(C14 When used in conjunction with the Blind)/+4to+59( When used with a vertical perforated plate)/+4to+40( when used With horizontal hole bottom plate) | |||||
mm | max .Φ710 | max .Φ1000 | max .Φ1280 | |||
mm | max.700×700 | max.1000×1000 | max.1200×1200 | |||
(W*D*H)mm | 800×800×950 | 1100×1100×950 | 1400×1400×1100 | |||
(W*D*H)mm | 1225×2890×2150 | 1525×3590×2150 | 1825×3950×2300 | |||
400V±10%,50HZ,3/N/PE | ||||||
KW | 11/16/20 | 14/20/24 | 21/24/30 | 24/26/32 | 26/35/54 | 34/44/65 |
Water-cooled |