Add to Cart
Sand Dust Test Chamber IEC60529 Dustproof Test for enclosure protection
Sand Dust Test Chamber, also known as "dust chamber", it simulates the destructive effect of natural wind and sand environment on products, and is used to test the sealing performance of product enclosures. The chamber tests comply to IEC60529-2013 13.5 & 13.6
Sanwood Sand Dust test chamber features
1. Chamber inner material: mirror SUS304 stainless steel;
2. Chamber external material: surface atomization SUS304 stainless steel;
3. Chamber observation window from toughened glass.
4. Outreach controller can set time and temperature
5. Equip with air switch to prevent overcurrent and short circuit, dustproof socket
6. Wiper: the dust adhearing to the wall can be wiped to maintain the concentration required for the test.
7. Safety device: leakage power-off protection, overload fuse protection, fan overheating protection;
Sanwood Sand Dust Test chamber Specifications
Item | SM-SC-1500 |
Internal dimension | 1000W*1000H*1500Dmm |
External dimension | 1400W*1650H*2400D mm |
Chamber material | SUS304 Stainless steel |
Specifications of square mesh sieve | Mesh hole 75um, mesh metal wire diameter 50um |
Talcum powder amount | 2 ~4 kg/ m2 |
Airflow speed | No more than 2m/s |
Door | Left open door with tempered glass door |
Controller | PLC Touch Screen controller, programmable to set as below cycle: a. Blowing dust time (Stop/Blow) m/s b. Cycle time: can be adjusted c. Pre-set test time: 0s ~99m99s |
Vacuum system | Pressure gauge, air filter, Pressure regulating FRL, connecting pipe, Vacuum pump |
Fan | Centrifugal fan |
Safety protection devices | Meter over-temperature function, Phase shortage protection, Power short-circuit protection |
Power supply | Standard: 380V AC, 50Hz three phase Power supply vailable for the other countries in the world. |
The whole air duct is made of imported high-grade stainless steel plate, the bottom of the air duct is connected with the conical hopper interface, the air inlet and outlet of the fan are directly connected with the air duct, and then the diffusion port on the top of the working room is connected to the working room body at an appropriate position to form an "O" type closed vertical dust blowing circulation system, Make the air flow smoothly, make the dust disperse evenly to the maximum extent. A single high-power low-noise centrifugal fan is used, and the frequency converter is used to adjust the wind speed according to the test requirements.
Product Catalog:
Dust Test Chamber.pdf